Reusable Pen by Pharmacona – Reusable Injection Pen for 3 ml Cartridges
Practitioner Recommended

Reusable Pen by Pharmacona – Reusable Injection Pen for 3 ml Cartridges

Reusable Pen is a reusable, mechanical injection device for standard 3 ml cartridges, enabling precise, incremental dosing of peptides, HGH and other active substances. The device features an integrated needle guard, is designed for multiple uses and meets the hygiene requirements of the medical profession.

€40.00Free shipping on orders over €300
In stock
Ships within 48 h Lab-tested batch
  • Incremental dose adjustment minimises deviations in active substance administration.
  • Reusable design reduces consumable waste compared to disposable pens.
  • Needle guard function prevents accidental triggering and needle-stick injuries.
  • Universal 3 ml cartridge compatibility allows use with a variety of substance classes.
  • Transparent cartridge window enables visual fill-level monitoring without disassembly.
  • Screw-fixing secures the cartridge reliably and prevents incorrect fitting.
  • Chemically resistant housing material ensures dimensional stability on contact with reconstitution solutions.

Key takeaways

  • Enables precise dosing in defined increments from 3 ml cartridges.
  • Integrated needle guard reduces the risk of needle-stick injuries during handling.
  • Compatible with HGH, peptide and GLP-1 cartridge formats.
  • Reusable housing made from medical-grade polycarbonate, chemically resistant.
  • Cartridge changes require no tools and take under 60 seconds.

Product Description: Reusable Pen for 3 ml Cartridges

Reusable Pen is a mechanical injection device designed specifically for use with standardised 3 ml cartridges, enabling controlled, reproducible administration of peptides, HGH preparations and GLP-1 analogues. The device operates on a stepped ratchet mechanism: the user turns the dose dial to the desired value, attaches a compatible pen needle and performs the injection subcutaneously. The set dose is delivered precisely by the mechanical plunger drive, minimising the risk of over- or under-dosing.

The pen accepts standard 3 ml glass cartridges, as used with Norditropin, Genotropin and comparable growth hormone preparations, as well as lyophilised peptide formulations (e.g. BPC-157, TB-500 after reconstitution). The cartridge is inserted into the pen body and secured by a screw-fixing system; a cartridge change takes under 60 seconds in practice. The dose dial allows settings in defined increments (typically 0.01–0.1 ml per step, depending on cartridge format), enabling individually tailored dosing without additional measuring equipment.

Construction Features and Safety Standards

The Reusable Pen features an integrated needle guard (needle cap retention system) that prevents accidental triggering of the injection and protects the user from needle-stick injuries. The housing is made from medical-grade polycarbonate, which is chemically resistant to common reconstitution solutions (water for injections, bacteriostatic water, 0.9% NaCl). All product-contact internal components are made from pharmaceutically approved materials; the pen is sterilisable and designed for repeated use. The mechanical precision of the ratchet mechanism meets the dosing accuracy requirements of ISO 11608-1 (needle requirements for injection systems) and ensures a deviation of less than ±2% from the set dose value.

Application Area and Compatibility

Reusable Pen is suitable for all subcutaneous applications using standard 3 ml cartridges. Compatible product groups include recombinant growth hormones (HGH) in cartridge form, reconstituted peptides (BPC-157, TB-500, CJC-1295, Ipamorelin) and semaglutide and tirzepatide formulations in cartridge format. The device is not designed for disposable pre-filled pens and is not compatible with ampoules or vials. The use of pen needles sized 29G–32G × 4–8 mm is recommended; these are available separately. The pen is supplied as a single unit (1 pen), without cartridge and without needles.

Usage

  1. Prepare the cartridge: Reconstitute the cartridge according to the manufacturer's instructions (if lyophilised) or remove directly from the refrigerator; inspect the cartridge for visible particles and discolouration.
  2. Insert the cartridge: Open the pen body, insert the cartridge plunger-end first, secure the screw-fixing by turning clockwise until it clicks into place.
  3. Attach the needle: Remove the protective cap from the pen needle (29G–32G × 4–8 mm), screw the needle onto the pen adapter; leave the outer needle cap in place for now.
  4. Set the dose: Turn the dose dial at the rear of the pen until the desired dose value (ml) appears in the viewing window; visually confirm the setting before injecting.
  5. Perform the injection: Remove the outer needle cap, disinfect the injection site, insert the needle subcutaneously at the recommended angle (45–90°), press the dose dial fully, hold for 5–10 seconds.
  6. After use: Dispose of the needle safely (sharps container), replace the needle cap, clean the pen with an alcohol swab if needed, store the cartridge with remaining content according to the substance's storage conditions.

Warnings

Contraindications

  • The device must not be used if the cartridge shows visible particles, cloudiness or damage.
  • Not suitable for intramuscular or intravenous administration.
  • Not intended for children under 12 years of age without supervision by a qualified professional.

Side Effects (device-related)

  • Incorrect operation of the dose dial may result in unintended over- or under-dosing.
  • Improperly attached needles may cause leakage at the cartridge-adapter connection.

Monitoring

  • Visually check the dose dial for the correct dose value before each injection.
  • Inspect the cartridge for remaining volume and integrity after each use.
  • Regularly check the pen mechanism for smooth operation; consider replacing the device if resistance is felt.

Notes

  • The pen is a medical device; repairs must not be carried out by the user.
  • Do not autoclave the pen; clean outer surfaces only, using alcohol swabs.
  • Needles are single-use items and must not be reused.
  • Store at room temperature (15–25 °C), protected from direct sunlight.
  • This device does not replace medical advice regarding dosing and indication.

Frequently asked questions

Which cartridge sizes are compatible with the Reusable Pen?
The Reusable Pen is designed exclusively for standard 3 ml glass cartridges. Cartridges of other volumes (e.g. 1.5 ml or 10 ml), glass vials or disposable pre-filled pens are not compatible. Before use, ensure that the cartridge conforms to the standard 3 ml format and shows no visible damage.
Which pen needles are suitable for this device?
Pen needles sized 29G to 32G with a length of 4 to 8 mm are recommended, as standardly used for subcutaneous injections. Needles must be sourced separately and disposed of safely in a sharps container after each injection. The use of compatible screw-on needles is essential for a leak-free connection.
How should the pen be cleaned between uses?
The outer surfaces of the pen should be wiped down with an alcohol swab after each use. Sterilisation by autoclaving or immersion in disinfectant solutions is not permitted and may damage the housing material. The used needle is removed after each injection and disposed of in a suitable sharps container.
Can the Reusable Pen be used alternately with different substances?
Changing substances requires replacing the cartridge and thoroughly cleaning the product-contact internal surfaces. To avoid cross-contamination, it is recommended to use a separate pen for each substance class. If there is any uncertainty regarding compatibility and cleaning protocols, consult a qualified professional.
How accurate is the dose setting of the mechanical ratchet mechanism?
The ratchet mechanism of the Reusable Pen delivers dosing accuracy with a deviation of less than ±2% from the set dose value, in line with the requirements of ISO 11608-1. The increment is 0.01 ml or 0.1 ml per click position, depending on the setting. A visual check of the dose dial before each injection is strongly recommended.

Manufacturer

Pharmacona is a manufacturer specialising in pharmaceutical application systems, developing and producing injection devices for use with standardised cartridge formats. The Reusable Pen is manufactured under controlled production conditions and complies with the requirements of the ISO 11608 series of standards for needle injection systems. Pharmacona focuses on specialist trade distribution and the supply of users who require precise application aids for peptides, HGH and GLP-1 analogues. Quality control and material selection follow pharmaceutical industry standards.

Product details

BrandPharmacona
Also known asInjektionspen, Insulin-Pen, wiederverwendbarer Pen, Karpulen-Pen, Reusable Pen, Pharmacona Pen
FormGerät
Item numberOTHER-XXX-PHA-001

Reviews

No reviews yet. Be the first to review this product.

Write a review

Your rating *

Your review will be checked before publication.

Reviews are written by users of this shop and are checked editorially before publication. Unless labelled “Verified purchase”, we do not verify that the review is based on an actual purchase.

Similar products

Stack it with

Pairs well with these products.

Quant-Equipoise 300mg/ml 10ml Vial by Beligas PharmaceuticalsHigh Concentration

Quant-Equipoise 300mg/ml 10ml Vial by Beligas Pharmaceuticals

€47.00
Bolden-250 250mg/ml 10x1ml Ampoules by BM PharmaceuticalsLong-Acting Formula

Bolden-250 250mg/ml 10x1ml Ampullen by BM Pharmaceuticals

€48.00
EquiTrex 350mg/ml 10ml Vial by Concentrex LabsBrand Quality

EquiTrex 350mg/ml 10ml Vial by Concentrex Labs

€52.00
EQ 300 300mg/ml 10ml Vial by Dragon-PharmaPro Choice

EQ 300 300mg/ml 10ml Vial by Dragon-Pharma

€44.00